Numéro
J. Phys. Colloques
Volume 48, Numéro C7, Décembre 1987
1st International Laser M2P Conference
Page(s) C7-769 - C7-769
DOI https://doi.org/10.1051/jphyscol:19877192
1st International Laser M2P Conference

J. Phys. Colloques 48 (1987) C7-769-C7-769

DOI: 10.1051/jphyscol:19877192

INTRACAVITY SPECTROSCOPY WITH MODULATED MULTIMODE LASERS

V.M. BAEV1, J. ESCHNER2, P.E. TOSCHEK2 and A. WEILER2

1  Lebedev Physical, Institute of the Academy of Sciences of the USSR, Leninsky 5, 117924 Moscow, USSR
2  Institut für Experimentalphysik, Universität Hamburg, Jungiusstrasse 9, D-2000 Hamburg 36, F.R.G.


Abstract
Successful application of intracavity spectroscopy is based on its high sensitivity and linearity. Unfortunately a number of experiments revealed recently nonlinearities of intracavity measurements appearing as complex asymmetric line shapes, sometimes with spectral condensation on one or both wings of an absorption line. We found that this spectral condensation is a result of phase lccking of mode groups near the absorption line. Mode locking originates from the interaction of the laser light with a strong inhomogeneously broadened absorber.