SENSITIVE AREA OF A BACK-SCATER-TYPE GAS FLOW DETECTOR FOR CONVERSION ELECTRON MÖSSBAUER SPECTROMETRY

M. Inaba, K. Nomura et Y. Ujihira

Faculty of Engineering, the University of Tokyo, 7-3-1 Hongo, Tokyo, Japan


Abstract
Counting characteristics of a back-scatter-type detector for CEMS were studied in terms of a sample position, a distance from a sample to a source, a window diameter of a detector etc.. Useful information on a position sensitivity was obtained for the better sample setting in a detector.