Issue |
J. Phys. Colloques
Volume 41, Number C1, Janvier 1980
International Conference on Mössbauer Spectroscopy
|
|
---|---|---|
Page(s) | C1-59 - C1-59 | |
DOI | https://doi.org/10.1051/jphyscol:1980110 |
International Conference on Mössbauer Spectroscopy
J. Phys. Colloques 41 (1980) C1-59-C1-59
DOI: 10.1051/jphyscol:1980110
1 Physics Department, Rice University, Houston, Tex 77001, USA
2 II. Institut fur Experimentalphysik, Universitat Hamburg, Germany
J. Phys. Colloques 41 (1980) C1-59-C1-59
DOI: 10.1051/jphyscol:1980110
IMPEDANCE MATCHED GRAZING INCIDENCE FILMS : PURE NUCLEAR REFLECTIONS, RESONANT FILTERING OF SYNCHROTRON RADIATION, AND X-RAY INTERFEROMETRY
J.P. Hannon1, G.T. Trammel1, N. Mueller2, E. Geradu2, H. Winkler2 et R. Ruffer21 Physics Department, Rice University, Houston, Tex 77001, USA
2 II. Institut fur Experimentalphysik, Universitat Hamburg, Germany
Abstract
The purpose of this letter is to point out the possibility of a new interference technique in X-ray and γ-ray optics - the simple idea of impedance matched grazing incidence films - and to discuss applications to pure nuclear coherent reflections, resonant filtering of synchrotron radiation, and X-ray interferometry.