X-Ray and Inner-Shell Processes
Vol. 1
J. Phys. Colloques 48 (1987) C9-69-C9-74
DOI: 10.1051/jphyscol:1987908
RSY DEDICATED STIGMATIC MONOCHROMATORS
M. POUEYLaboratoire de Physique des Gaz et Plasmas, Université Paris-XI, Bât. 212, F-91405 Orsay Cedex, France
Abstract
In this paper we describe new STIGMATIC XUV monochromators specially designed to fit the "Etendue" of SUPER ACO. Fixed horizontal and vertical diffracted beam divergences, as well as uniform photometric illumination are allowed ; comparison with TGM show the improvements that might be expected from the case of Plane type V grating used in convergent light.